If the indoor unit runs but the outdoor unit is not running, the system can’t heat or cool: you’ll get room-temperature air from the fan. Check the isolator switch beside the outdoor unit and the circuit breaker first. If both are on, the likely causes are a failed capacitor, a failed contactor, a fan motor fault, a protection lockout or a communication fault between the units. All of these need a technician; the outdoor unit contains live electrical parts and refrigerant under pressure.

Checks you can do safely
- Mode: the outdoor unit only runs in cool, heat or dry, not fan mode.
- Isolator: the weatherproof switch on the wall beside the outdoor unit must be on.
- Circuit breaker: some systems have a separate breaker for the outdoor unit. Reset it once only.
- Wait: many systems delay the outdoor unit for a few minutes after start-up to protect the compressor.
- Error code: check the indoor unit for a flashing lamp and note the pattern.
Causes and what each one needs
| Cause | What you’ll notice | Who fixes it |
|---|---|---|
| Isolator off or breaker tripped | Outdoor unit silent | You (once); technician if it trips again |
| Failed capacitor | Humming, but the fan and compressor don’t start | Technician |
| Failed contactor or relay | Silent, or clicks without starting | Technician |
| Outdoor fan motor fault | Compressor hums, fan still; unit overheats and stops | Technician |
| Communication fault between units | Error code; indoor fan runs | Technician |
| High-pressure or overheat protection | Runs, then stops on hot days; restarts later | Clear the coil; technician if it continues |
| Compressor failure | Fan runs, compressor never starts, no cooling | Technician; see compressor cost |
Do not remove the outdoor unit’s covers. Capacitors can hold a charge even with the power off.