Air Conditioner Not Cooling? Causes, From Easy to Serious

Air conditioner not cooling? Check mode, filters and the outdoor unit first, then the signs of low gas or a failed part.

Call 03 9088 4796Request a Quote

If your air conditioner runs but is not cooling, check that the mode is set to cool (the snowflake), the filters are clean, and the outdoor unit is running and clear of leaves and clutter. If the outdoor fan isn’t spinning, the pipes are icing up, or the air stays warm after those checks, the unit needs a technician. The usual causes then are a failed fan or capacitor, a refrigerant leak, or a compressor fault.

Air conditioner not cooling guide by Rapid Air Cooling

Work through the checks first. They fix a large share of “not cooling” problems without a call-out.

Five checks first

  1. Mode and set temperature. Make sure the remote shows cool, not fan, dry or auto, and that the set temperature is below the room temperature. A setting of 23 to 25 degrees is realistic on a hot day.
  2. Filters. Pull the filters out. If they are grey or matted, vacuum and rinse them, let them dry, and refit. A blocked filter is a common cause of poor cooling.
  3. Outdoor unit. With the system cooling, the outdoor fan should spin and you should feel warm air leaving it. Clear anything within a hand span of the coil.
  4. Doors, windows and sun. A unit sized for one room will struggle with an open plan area, open doors or full afternoon sun on west-facing glass.
  5. Give it time. After a hot day, walls and furniture hold heat. Allow 20 to 30 minutes before judging.

Causes and what each one needs

CauseWhat you’ll noticeDIY or technician
Wrong mode or set temperatureFan runs, air is room temperatureDIY
Dirty filtersWeak airflow, sometimes ice on the indoor coilDIY
Blocked or dirty outdoor coilOutdoor unit runs hot; cooling fades on hot afternoonsDIY clear-around; technician to clean the coil
Outdoor fan or capacitor failedOutdoor unit hums but the fan doesn’t spinTechnician
Refrigerant leak (low gas)Cooling gets weaker over weeks; ice on pipes; hissingTechnician (ARCtick-licensed)
Frozen indoor coilIce on the pipes or coil, water dripping laterSwitch to fan mode to thaw; find the cause
Compressor or control faultOutdoor fan runs but no cooling; error codeTechnician
Unit too small for the spaceRuns flat out all day and never reaches the set temperatureTechnician to assess sizing

Is it low on gas?

Refrigerant does not get used up. If a system is short of gas, it has a leak. Topping it up without finding the leak only buys time. Signs include cooling that fades over weeks, ice on the thin copper pipe at the outdoor unit, and a hissing or bubbling sound.

In Australia only an ARCtick-licensed technician can handle refrigerant. A proper repair finds and fixes the leak, then evacuates and recharges the system to the manufacturer’s specified amount.

Not cooling on very hot days

Every system has a rated capacity. On a 40 degree day with the sun on the glass, a correctly sized unit may only hold the room a few degrees below outside, and an undersized one may not manage that. If the unit cools well on mild days and struggles only in extreme heat, the cause may be sizing or a dirty outdoor coil rather than a fault.

Brand guides

When to call a technician

Call if the outdoor fan isn’t turning, there is ice on the pipes after the filters are clean, a breaker trips, or cooling keeps getting weaker. If the system is old and the diagnosis points to the compressor, read whether it is worth repairing an old AC before deciding.

Book a technician online or start from our troubleshooting hub for other symptoms.

In Australia, refrigerant work must be done by a technician who holds an ARC licence. You can read more about licensing on the ARCtick website.